Informational page for pre approved standard plans.
City of los angeles standard retaining wall detail.
Concrete block units to be staggered running bond.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
San diego municipal code chapter 14 article 2.
City of los angeles electrical plan check correction list.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.
Metal bin type retaining wall.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
Retaining or slough wall 4 foot high or less 178 kb view.
City of los angeles electrical plan check correction list.
Disabled access standard details notes for commercial buildings.
Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
The height of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
Reinforcing steel shall be deformed steel conforming to a s t m.
213 847 0700.
Page 1 of 2 retaining or slough wall 4 0 high or less.
Concrete block units shall conform to astm c90.
Build safe well and fast with the city of los angeles department of building and safety.
Alternative design procedures justified in a geotechnical report may also be approved.
If any information on any of the standard plans is not legible it is the user s responsibility to obtain a legible copy from the bureau of engineering vault located at.
Concrete mix for footing to be 1 part cement to 2 5 parts sand to 3 5 parts gravel with a maximum of 7 5 gallons of water per sack of cement minimum f c 2 500 psi.
Lap all steel 16.
Plumbing plan check correction list for 2017 codes 422 kb view.
Multiple cover details for sanitary sewer manholes.
Concrete block units to have vertical continuity of the cells unobstructed.
Each series contains several standard plans.
Soil lateral loads labc 1610 1 general.
Acceptable engineering criteria for retaining wall design.
The standard plans are divided into several series.