The insulation is below the deck but above the plasterboard.
Cold flat roof insulation thickness.
This may help with condensation but causes such a loss of heat that it has been banned in scotland.
With a flat roof this issue does not arise but the u value constraint and the amount of insulation needed is just the same.
This is used for refurbishment e g.
The waterproof layer is above the insulation and a vapour control layer is placed below the insulation.
Cold roofs have the waterproof layer placed directly onto the roof deck and the insulation inside the roof just above the ceiling.
Alternatively battens can be secured to the underside of the.
There are two basic categories of roof design.
Warm flat roof insulation.
Refurbishing an existing timber joisted flat roof which has no insulation.
Cold deck this is where the insulation is placed between the joists rafters or in between the ceiling joists in the case of a pitch roof.
A cold flat roof is one where the insulation is between or between and below the roof joists.
Ventilation is required for these roofs.
Warm deck the type of insulation for this is usually of a rigid type and the thickness will vary depending on the manufacturer s specifications.
This means there is a vapour control layer in the ceiling and cross ventilation at the eaves or the top of the walls.
Many properties use this option as there are no additional costs for scaffolding or organising how to gain safe access to the roof exterior.
Saint gobain insulation uk manufacture and supply glass mineral wool slabs and rolls along with rigid polyisocyanurate pir boards that can be considered suitable for a wide range of applications across flat roofs whether you re looking to insulate at joist level or above the roof deck in your flat roof construction.
A cold roof has the insulation placed below the structural deck which thus remains cold.
Cold flat roof insulation.
The insulation material is placed between the supporting joists leaving a gap of 50 60mm between the roof and insulation.
There are two types of flat roof.
A warm roof has the insulation above the structural deck which is thus kept warm.
In this case ventilation is required and the roof can still become wet with condensation which may cause materials to decay.
Cold roofs and warm roofs.
Lots of traditional flat roofs are of the cold roof construction type.
A ventilation gap usually 50mm should be provided between the top of the insulation and underside of the roof covering to allow the air to flow across.
It allows insulation to be added without having to replace the waterproofing on.
Achieving a u value of 0 20w m meaning your roof will be better insulated than your walls will need 120mm thickness of rigid foam or 200mm of mineral wool or natural insulation.